Manitowoc Ice QM45 Series User Manual

Page 26

Advertising
background image

4-4

Maintenance

Section 4

F. Remove the Water Trough

• Apply downward pressure on the siphon tube and

remove from the bottom of the water trough.

• Remove the upper thumbscrew.

• While supporting the water trough remove the

two thumbscrews from beneath the water trough.

• Remove the water trough from the bin area

G. Remove the Ice Damper

• Grasp ice damper and apply pressure toward the

left hand mounting bracket.

• Apply pressure to the right hand mounting

bracket with thumb.

• Pull ice damper forward when the right hand ice

damper pin disengages.

Installation

• Place ice damper pin in left hand mounting

bracket and apply pressure toward the left hand
mounting bracket.

• Apply pressure to the right hand mounting

bracket with thumb.

• Push ice damper toward evaporator until right

hand damper pin engages.

SV1689-1

UPPER

THUMBSCREW

REMOVE SIPHON

TUBE

LOWER

THUMBSCREWS

Advertising