2) Program example 2

If the moving distance of the "ITP" command is less than the moving distance necessary for
deceleration, the actual deceleration time constant becomes less than the set value of the "STB"
command.

Program

Description

SPN (500)
STA (200)
STB (300)
MOV (1000)
SYNC (1)
ITP (50)
STOP

Speed (Motor speed)

500 [r/min]

Acceleration time constant

200 [ms]

Deceleration time constant

300 [ms]

Absolute move command

1000 [ 10

STM

m]

Step is suspended until Program input (PI1) turns ON.

a)

Interrupt positioning command

50 [ 10

STM

m]

b)

Program end

0r/min

ON

OFF

Servo motor
speed

Forward
rotation

Program input1
(PI1)

P1

P1 b)

Waiting for PI1 to be turned ON
by SYNC(1) (a))

(50 10

STM

m)

(f) External pulse counter (COUNT)

When the number of input pulses of the manual pulse generator becomes greater than the value
set with the "COUNT" command, the next step is started. Set "0" to erase the accumulated input
pulses.

Program

Description

COUNT (500)

SPN (500)
STA (200)
STB (300)
MOV (1000)
TRIP (500)
COUNT (0)
STOP

The next step is held until the number of input pulses of the manual pulse generator reaches
500 [pulses].

a)

Speed (Motor speed)

500 [r/min]

Acceleration time constant

200 [ms]

Deceleration time constant

300 [ms]

Absolute move command

1000 [ 10

STM

m]

Trip point

500 [ 10

STM

m]

b)

Waiting for PI1 to be turned ON by SYNC(1) (a))

c)

Program end

0r/min

³

“]

ƒ

T [ ƒ

{ ƒ

‚ [ ƒ

^

ñ

“] ‘¬ “x

ON

OFF

b) 500 [ 10

STM

m]

Manual pulse
generator

a) 500 [pulse]

c) Accumulated input pulses are erased.