14. OPTIONS AND AUXILIARY EQUIPMENT

(4) Connection of the regenerative brake option

The regenerative brake option will generate heat of about 100 . Fully examine heat dissipation,
installation position, used cables, etc. before installing the option. For wiring, use flame-resistant
cables and keep them clear of the regenerative brake option body. Always use twisted cables of max.
5m(16.4ft) length for connection with the servo amplifier.
(a) MR-J2S-350CL or less

Always remove the wiring from across P-D and fit the regenerative brake option across P-C.
The G3 and G4 terminals act as a thermal protector. G3-G4 are disconnected when the
regenerative brake option overheats abnormally.

Servo amplifier

Regenerative brake option

Note: 1. When using the MR-RB50, forcibly cool it with a cooling fan (1.0m

3

/min, 92 or so).

2. Make up a sequence which will switch off the magnetic contactor (MC) when
abnormal heating occurs.

(Note2)

5m (16.4 ft) max.

D

P

P

C

G3

G4

C

Always remove the lead from across P-D.

G3-G4 contact specifications
Maximum voltage: 120V AC/DC
Maximum current: 0.5A/4.8VDC
Maximum capacity: 2.4VA

Fan (Note 1)

For the MR-RB50 install the cooling fan as shown.

82.5

40 (1.58)

82

.5

13

3

Fan installation screw hole dimensions

2-M3 screw hole

(for fan installation)
Depth 10 or less
(Screw hole already

machined)

Recommended fan:
Toyo Denki's TL396A or equivalent

Fan

Terminal block

Thermal relay

Installation surface

Horizontal installation

Vertical

installation

Top

Bottom

(3

.25

)

(5

.24

)

(3.25)

[Unit : mm(in)]