1. installing welding generator, 2. connecting the battery – Miller Electric Big Blue 600D User Manual

Page 17

Advertising
background image

OM-481 Page 13

SECTION 4 – INSTALLATION

4-1.

Installing Welding Generator

install1 7/02 – Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854

Electrically bond generator frame to
vehicle frame by metal-to-metal
contact.

GND/PE

1

2

Y

Always securely fasten
welding generator onto
transport vehicle or trailer
and comply with all DOT and
other applicable codes.

Y

Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.

Y

If unit does not have GFCI re-
ceptacles, use GFCI-
protected extension cord.

1

Equipment Grounding
Terminal (On Front Panel)

2

Grounding Cable (Not
Supplied)

3

Metal Vehicle Frame

Connect cable from equipment
ground terminal to metal vehicle
frame. Use #10 AWG or larger
insulated copper wire.

3

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

OR

Movement

Airflow Clearance

Location

Grounding

OR

Y

Do Not Lift Unit From End

4-2.

Connecting The Battery

1/2 in

+

Y

Connect Negative (–)
Cable Last.

Tools Needed:

ST-153 654-B / Ref. SD-131 784-A / Ref. S-0756-B

OFF

START

RUN

Advertising