7
Note: Any cables connected to the computer should be shielded to reduce
interference.
Diagnostics
Power-on self test, local analog loop, local digital loop, remote digital loop.
Indicators
LEDs for Transmit Data, Receive Data, Carrier Detect, 56K bps, 33.6K bps,
14.4K bps, Off Hook, Terminal Ready, Error Correction, Fax.
Speaker
Internal speaker for call progress monitoring.
Manual Control Power
switch
Operating Temperature
-40°– 60°C (-40°–140°F) ambient under closed conditions; humidity range 20–
90% (non-condensing)
Power Requirements
Global modems: 100–240 VAC, 50/60 Hz universal power supply
Non-global modems: 115 VAC, 60 Hz or 230 VAC, 50 Hz power supply
Power Consumption
9 VDC, 300 mA maximum
Dimensions
10.8 cm wide x 14.8 cm long x 2.9 cm high (4.25" x 5.8" x 1.15")
Weight
224 g (8 oz)
Limited Warranty 10