Maximum throughput setting, Originate/answer mode, Request to send forced – Multi-Tech Systems MT2834BL User Manual

Page 80: Slave clocking

Advertising
background image

80

Chapter 8 - Dip-Switch Settings

Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide

Switch #5
Originate/Answer Mode
(Asynchronous/Synchronous Mode/Leased Line)

The modem functions in either Originate mode or Answer mode. Place DIP-Switch #5 in the DOWN
position to enable Originate mode. Place DIP-Switch #5 in the UP position to enable Answer mode.

Originate Mode Enabled

=

Switch #5 DOWN

Answer Mode Enabled

=

Switch #5 UP

(Factory Default Setting

=

UP)

Switch #6
Maximum Throughput Setting
(Asynchronous Mode/Leased Line/Dial-Up)

Some applications require you to dial into services with maximum throughput on, and other
applications where maximum throughput must be off (i.e., service not supporting error correction, or
the V.42 handshake interferes with logon sequence). DIP-Switch #6 is used for switching between
these two modes. This DIP-Switch controls three important parameters (error correction, speed
conversion and serial port speed), which in effect enables or disables maximum throughput.

Maximum Throughput Enabled =

Switch #6 UP

Maximum Throughput Disabled =

Switch #6 DOWN

Factory Default Setting

=

UP

Switch #6
Slave Clocking
(Synchronous Mode/Leased Line/Dial-Up)

In Synchronous mode, DIP-Switch #6 controls the option of having timing controlled by the receive
clock. The originate modem, in effect, adjusts to the answer (remote) modem. Place DIP-Switch #6 in
the DOWN position to enable Slave Clocking. Place DIP-Switch #6 in the UP position to disable
Slave Clocking.

Slave Clocking Enabled

=

Switch #6 DOWN

Slave Clocking Disabled

=

Switch #6 UP

Factory Default Setting

=

UP

Switch #7
Request To Send Forced - "RTS"
(Asynchronous/Synchronous Mode/Leased Line/Dial-Up)

If your computer or terminal uses RTS-CTS protocol (typically used in some synchronous
applications, but also if using hardware pacing for V.42 error correction or speed conversion), you
may want to set RTS to function independently of CTS (DIP-Switch #7 UP). For most applications,
especially asynchronous, this switch should be set so that RTS is forced On (DIP-Switch #7 DOWN)

RTS functions Normally

=

Switch #7 UP

RTS forced On

=

Switch #7 DOWN

Factory Default Setting

=

DOWN

Advertising