3-8. Electrical Service Guide For 230 VAC Model

Input Voltage

230

Input Amperes At Rated Output

20

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

20

Min Input Conductor Size In AWG/Kcmil

14

Max Recommended Input Conductor Length In Feet (Meters)

66 (20)

Min Grounding Conductor Size In AWG/Kcmil

12

Reference: 1996 National Electrical Code (NEC)

S-0092-J

3-9. Installing Wire Spool And Adjusting Hub Tension

S-0499

15/16 in

Standard Wire Spool (8 in)

1 Lb Wire Spool (4 in)

Turn wingnut. When a slight force is

needed to turn spool, tension is set.

Tools Needed:

Adjusting Hub Tension

Install spool so welding wire feeds from bottom.

Advertising