Installation (cont.) – Moyer Diebel M-DH User Manual

Page 10

Advertising
background image

4

!

INSTALLATION

INSTALLATION (CONT.)

Plumbing Connections

NOTE:
Plumbing connections must comply with all applicable sanitary and plumbing codes.

Water Connections

1. All M-DH dishwashers require a single, hot water supply.

2. The hot water connection to the dishwasher is 1/2” BSP male.

3. The connection is made from underneath the dishwasher.

4. The recommended minimum water temperature is 140F/60°C.

5. A manual shut-off valve for water (supplied by others) should be installed in the supply

line to allow for servicing of the machine. The shut-off valve should be the same size or
larger than the supply line.

6. Install a pressure reducing valve (PRV) in the water supply line if flow pressure exceeds

20-22 PSI/138-151.8kPa.

Drain Connections

1. The dishwasher is a gravity drain machine equipped with 1-1/2” O.D. hose connection

point.

2. The maximum drain flow rate is 15 gallons/min-56.8 liters/min.

3. Drain height for the dishwasher must not exceed 11” (280mm) above the floor level.

4. The drain connection is made to the dishwasher from behind the machine or through an

access hole in the base of the machine.

Ventilation

NOTE:

Ventilation must comply with local sanitary and plumbing codes.

CAUTION:
Exhaust air should not be vented into a wall, ceiling, or concealed space of a building.
Condensation can cause damage.