6. installing non-pd (old style) wire guides – Miller Electric AA40GBU User Manual

Page 16

Advertising
background image

OM-227 674 Page 12

3-6. Installing Non-PD (Old Style) Wire Guides

Ref. 804 192-B / 804 188-A

Installing wire guides with non-

PD (old-style) drive rolls

.

Non-PD (old-style) wire guides

and drive rolls should be used

with 5/64 in (2.0 mm) and larger

diameter wire.

1

Pressure Assembly Door

2

PD Inlet Guide

3

Intermediate Guide

4

Set Screw

5

Guide Holder

6

Exit Guide

Open pressure assembly door.
Lift up drive roll swing arms.
Install PD inlet guide.

.

Do not tighten set screw to se-

cure inlet guide.

.

Set screw may be used to se-
cure PD inlet guide replace-

ments such as wire straighten-

ers or conduit adapters.

Remove screw securing intermedi-

ate guide holder. (Guide holder is

located between the lower front

and rear drive roll carriers.)
Rotate guide holder 180 degrees

and reinstall.
Install intermediate guide into guide

holder and tighten set screw.
Loosen set screw, insert exit guide

into block near brass power pin gun

connection and secure with set

screw.

.

When using smaller diameter

inlet guide (219108) with non-

PD (old style) drive rolls, a 1/4

in (6 mm) gap will be present

between the guide and drive

roll.

1

Tools Needed:

1/16, 1/8, 5/32 in

6

5

3

2

4

Advertising