To convert the burners

Turn off the main gas supply (if the
appliance has already been in-
stalled) and disconnect the appli-
ance from the main electrial power
supply before proceeding.

The following orifices and needle valves
should be installed into their respective
burners.

Conversion table KM 342

Code

Orifice

size

(Ø mm)

Code

Needle

valve

size

(Ø mm)

Natural gas

Normal
burner

140

1.40

62

0.62

Fast burner

167

1.67

78

0.78

Wok burner

inner
outer

34

190

No. 34

1.90

40
88

0.40
0.88

Propane (LP)

Normal
burner

90

0.90

41

0.41

Fast burner

103

1.03

45

0.45

Wok burner

inner
outer

7

109

No. 7

1.09

25
54

0.25
0.54

Save the orifices and needle valves re-
moved from the appliance for future
use.

Conversion table KM 344

Code Orifice

size

mm)

Code

Needle

valve

size

(Ø mm)

Natural gas

Normal
burner

140

1.40

62

0.62

Fast burner

167

1.67

78

0.78

Wok burner
left

inner
outer

34

190

No. 34

1.90

40
88

0.40
0.88

Wok burner
right

inner
outer

34

195

No. 34

1.95

40
88

0.40
0.88

Propane (LP)

Normal
burner

90

0.90

41

0.41

Fast burner

103

1.03

45

0.45

Wok burner
left

inner
outer

7

109

No. 7

1.09

25
54

0.25
0.54

Wok burner
right

inner
outer

7

112

No. 7

1.12

25
54

0.25
0.54

Converting to LP gas