53D9052

624WBPF Woodburning Fireplace

clearaNceS

FP2345
MPL features

Figure 3
Residential Installation

Chimney Cap

Roof Flashing

(Flue Outlet Height)

Storm Collar

14 ft. = Min. Height (No offsets)
14 ft. = Min. Height (2 30° Elbows)
21 ft. = Min. Height (4 30° Elbows)
86 ft. = Max. Height (Chimney support
every 35 ft.)

11CF1 (1 ft. pipe)
11CF18 (1Z\x ft. pipe)
11CF3 (3 ft. pipe)
11CF4 (4 ft. pipe)
Maintain 2” Minimum Air
Space Between Chimney
and Combustibles

Gas Line
(Optional)

Flexible Duct
Type FP-4-U

Combustion Air
Assembly (Optional)

Metal Safety Strip

(Floor Line)

Firestop
(Requires 17 x 17 framing)

Nail to Framing Mem-
bers Each Side

Firestop

1/2” Min. Air Space to
Combustibles

FP2345

Combustible materials should not be installed below
top spacer. Noncombustible materials such as brick
or tile may be used to trim face or the fireplace, com-
bustibles must not overlap the black painted face of
fireplace more than 1/8”.