This represents a typical response of the HM-1S and subwoofer out-of-phase phase, in a free field environment on-

axis at 1 meter. This measurement was performed in the large anechoic chamber at MSLI.

If your system response indicates a phase reversal please contact Meyer Sound Technical Support for assistance.

Half Space:

To verify the system performance in half space you must perform a ground-plane measurement. This type of

measurement is not desirable for system calibration and should only be used to verify the performance of the

subwoofer. Place the HM-1S next to the subwoofer on the flat ground and position the calibrated measurement

microphone one meter on axis from the tweeter of the HM-1S as pictured below:

Using noise or other broadband test signal, perform a transfer function of the HM-1S. Start with the subwoofer

disconnected.