6. weld cable connections, 7. input power connection – Miller Electric WC-115A User Manual

Page 16

Advertising
background image

OM-1078 Page 12

3-6. Weld Cable Connections

149 920-A / 151 113 / 801 487-A / Ref. 139 439-B

1

Grommet

2

Positive (+) Weld Output

Terminal On Welding Power

Source

3

Reed Switch

4

Weld Cable (Customer

Supplied)

5

Weld Cable Terminal

6

Weld Power Cable From

Gun/Feeder

7

Weld Power Grommet

Route weld cable and weld power

cable as shown. Be sure lug on

weld cable terminal and lug on

gun/feeder weld power cable make

contact with each other.
8

Contactor W1 (Optional)

Connect weld cable from welding

power source to unused W1

terminal.
Connect weld cable from W1 to

weld cable terminal.
Reinstall wrapper.

Tools Needed:

1/4 in

3/4 in

2

3

4

5

6

Rear View

1

Front Panel

Opening

7

+

Welding Power

Source

8

3-7. Input Power Connection

Ref. 149 548-D

1

Grounded Receptacle

A 15 ampere branch circuit

protected by time-delay fuses or

circuit breakers is required.
2

Input Power Cord And Plug

PLG4

Connect input power plug to a

proper receptacle.

1

2

Advertising