OM-232 386 Page 15

4-7.

Installing Gas Supply

Ref. 804 654-A / Ref. 804 898-A

Tools Needed:

Obtain gas cylinders and chain to
running gear, wall, or other
stationary support so cylinders
cannot fall and break off valve.

1

Cap

2

Cylinder Valve

Remove cap, stand to side of valve,
and open valve slightly. Gas flow
blows dust and dirt from valve.
Close valve.

3

Cylinder

4

Regulator/Flowmeter

Install so face is vertical.

5

Regulator/Flowmeter Gas
Hose Connection

6

Welding Power Source Gas
Hose Connection For MIG
Gun

Connect gas hose between
regulator/flowmeter gas hose
connection, and fitting on rear of
welding power source.

7

Gas Flow Adjustment Control

Typical flow rate is 25 cfh (cubic feet
per hour). Check wire
manufacturer’s recommended flow
rate.

8

CO2 Adapter (Customer
Supplied)

9

O-Ring (Customer Supplied)

Install adapter with O-ring between
regulator/flowmeter and CO

2

cylinder.

1-1/8, 5/8 in

Rear Panel

6

1

2

3

7

4

5

1

2

3

8

9

Argon Gas Or Mixed Gas

CO