Milwaukee 6560 Series User Manual

Page 4

Advertising
background image

6

7

WARNING!

Always lock trigger or remove

battery pack before changing or

removing accessories. Only use

accessories specifically recom-

mended for this tool. Others may

be hazardous.

Installing 10oz Carriage Frame Assem-

bly (Cat. No. 6560-21) (Fig. 3)
1. Lock trigger or remove battery pack.
2. Press in and hold rod release trigger.
3. Grasp plunger rod handle and pull

plunger rod back until the rod tip is just

inside of tool.

4. Release rod release trigger.
5. Thread barrel nut attached to tube

holder onto nose of the tool. Tighten

with spanner wrench by placing

wrench into two smaller holes in bar-

rel nut and turning clockwise.
NOTE: The frame cap, barrel nut, and

carriage frame are provided pre-as-

sembled.

ASSEMBLY

WARNING!

To reduce the risk of injury,

keep hands out of the plunger

area of the tool. Fingers can be

pinched between the tube holder

and the plunger.

Fig. 3

Plunger

Plunger rod

Nut

Carriage frame

Barrel nut

Nut

Frame cap

6. Press rod release trigger and push

plunger rod forward to access the

threads on rod.

7. Thread nuts and plunger onto the

plunger rod in order shown (Fig. 3).

Tighten back nut securely using the

wrench provided.
NOTE: Make sure the front nut and

plunger rod do not extend past the front

face of the plunger. If either part ex-

tends past the plunger, the back cap

of the material tube may rupture.

8. To remove carriage frame, reverse

procedure.

Front face of plunger

Front nut

Back nut

Plunger rod

6560-21

WARNING!

Charge only MILWAUKEE 12, 14.4

and 18 Volt battery packs in

MILWAUKEE chargers. Other

brands of batteries may explode

causing personal injury and

damage.
For specific charging instruc-

tions, please read the operator's

manual supplied with your

charger.

Inserting Battery Pack into Tool
For all models:
Battery pack can be inserted into the tool

in two ways.
1. For working in restricted spaces: In-

sert the battery pack from the front by

pressing in the release buttons and

sliding battery pack into the body of

the tool (Fig. 1). Insert the battery pack

until clamp engages.

2. For optimum weight distribution and

balance: Insert the battery pack from

the back by pressing in the release

buttons and sliding the battery pack

into the body of the tool (Fig. 2). Insert

the battery pack until clamp engages.

Fig. 2

Fig. 1

NOTE: A 12 volt battery is supplied with

this tool. To extend run time or increase

plunger speed, a 14.4 volt battery may be

used.