15

Minimum Allowable Window Position Required

To Avoid Detrimental Internal Reflective Beam Interference at

Negative Exit Beam Angle Tolerance


Exit Beam

Depression Angle β

Minimum Projected Distance (mm)

from the Engine’s Base to

the Window’s Internal Surface (M)

Minimum

Window Angle θ

-2.5° 5.0 23.5°

-2.5° 10.0 16.5°

-2.5° 15.0 12.5°

-2.5° 20.0 10.5°

-2.5° 25.0 9.0°

-2.5° 30.0 8.0°

-2.5° 35.0 7.5°

-2.5° 40.0 7.0°

-2.5° 45.0 6.5°

-2.5° 50.0 6.0°

Figure 13.

Specifications are subject to change without notice.