Continuous blinky mode, Sleep mode – Metrologic Instruments IS4823 User Manual

Page 22

Advertising
background image

18

Transmit “NO READ” Message on Laser Timeout

If the scanning cycle terminates without scanning a bar code during the cycle, a “NO READ” message is
transmitted with the termination of the scanning cycle.

Activate the LED During the “NO READ” Transmission

The LED is activated with the “NO READ” message. The LED is also activated after a successful scan.

Enable RTS “NO READ” Pulse

A configurable RTS pulse width transmitted after the “NO READ” message has been transmitted.

Detect and Notify Mode

The external I/O pin used in the default activation mode is monitored during the inactive laser cycles. An <SI>
is transmitted when the I/O is active and an <SO> when it is inactive. Once the scanning activation cycle is
started, the external I/O monitoring status is maintained until the scanning cycle is terminated regardless of the
actual I/O level.

Continuous Blinky Mode

The scanner will continuously blink on and off, turning the scanning cycle on and off for all normal scanner
operations. If a bar code is scanned and transmitted, the same symbol timeout is maintained throughout the
cycle preventing additional scans of the same bar code when the scanner is in default mode.

Sleep Mode

Sleep Mode is a power saving mode that can be configured to occur in 10-second increments.

Advertising
This manual is related to the following products: