Current draw @ 25°c, Is4825 dc operating voltages – Metrologic Instruments IS4823 User Manual

Page 28

Advertising
background image

24

IS4825 DC Operating Voltages

Signal

Signal Description

Minimum

Maximum

Condition

VIN

Operating Voltage

4.75V

5.25V

VIH(1)

Input High (RX, CTS)

2.5V

VIL(1)

Input Low (RX, CTS)

0.8V

VIH(2)

Input High (TTL_INV, nWake)

0.8 x Vin

VIL(2)

Input Low (TTL_INV, nWake)

0.8V

VIH(3)

Input High (EXT. Trigger)

0.8 x Vin

VIL(3)

Input Low (EXT. Trigger)

0.8V

VOH(1)

Output High Voltage (TX,RTS)

0.8 x Vin

Isource = 16 mA

VOL(1)

Output Low Voltage (TX,RTS)

0.14 x Vin

Isink = 16 mA

VOH(2)

Output High Voltage (nBeeper, nGoodRead)

***

3.6V or 5.5V

VOL(2)

Output Low Voltage (nBeeper, nGoodRead)

1.6V

Isink = 25 mA

VOH(3)

Output High Voltage (Power down)

***

3.6V or 5.5V

VOL(3)

Output Low Voltage (Power down)

0.2V

Isink = 8 mA

***

PWRDWN, nGoodRead, and nBeeper are open drain outputs w/ 100K pull-ups to VIN. Actual VOH will be determined

by the parallel resistance of the 100K pull up and any external impedance.

Current Draw @ 25°C

USB

TTL

Signal

Signal Description

VIN = 3.3V

VIN = 5V

VIN = 3.3V

VIN = 5V

Continuous
Scan mode

Average current draw during
continuous scan mode*

150 mA

130 mA

130 mA

130 mA

Stand By

Average current draw while in idle
mode

60 mA

72 mA

50 mA

45 mA

Sleep

Average current draw while in sleep
mode

50 mA

53 mA

5.5 mA

15 mA

Suspend

Mode (USB)

Average current draw in USB
suspend (USB version only)

5.5 mA

0.3 mA

N/A

N/A

*

Continuous Scan Mode current will vary based on object size, distance, and type.