20

Example 2:

The following sample illustrates the serial command sequence for configuring the engine for the factory
default settings, disabling Code 128 scanning, and adding a “G” as a configurable prefix.

Commands for features that require sequences of multiple bar codes for activation (i.e. prefixes, suffixes,
and timeout features) should be sent in the same order that they are normally scanned.

Feature Host

Command ASCII

Representation

Engine

Response

Enter Configuration Mode

[stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h

[ack] or 06h

Load Defaults

[stx]999998[etx]

02h 39h 39h 39h 39h 39h 38h 03h

[ack] or 06h

Disable Code 128

[stx]100103[etx]

02h 31h 30h 30h 31h 30h 33h 03h

[ack] or 06h

Configure Prefix #1

[stx]903500[etx]

02h 39h 30h 33h 35h 30h 30h 03h

[ack] or 06h

Code Byte 0

[stx]0[etx]

02h 30h 03h

[ack] or 06h

Code Byte 7

[stx]7[etx]

02h 37h 03h

[ack] or 06h

Code Byte 1

[stx]1[etx]

02h 31h 03h

[ack] or 06h

Exit Configuration Mode

[stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h

[ack] or 06h


Abbreviated ASCII Table

Character

Hex Value

Decimal Value

[STX] 02h

2

[ETX]

03h

3

[ACK] 06h

6

[NAK]

15h

21

0 30h

48

1

31h

49

2 32h

50

3

33h

51

4 34h

52

5

35h

53

6 36h

54

7

37h

55

8 38h

56

9

39h

57