21

General Design Specifications

Operational

Light Source: Visible Laser Diode (VLD) @ 650 nm

Laser Power: 1 mW

Depth of Scan Field: 50 mm – 254 mm (2" – 10") for 0.33 mm (13 mil) bar codes

57 mm (2.2") @ 50 mm (2") from engine face

Width of Scan Field:

264 mm (10.4") @ 254 mm (10") from engine face

Scan Speed: 100 Scan Lines per Second Typical

Scan Pattern: Single Scan Line

Minimum Bar Width: 0.10 mm (4.0 mil)

IS4813 and IS4815

Software Dependent

Symbologies Supported:

IS4823 and IS4825

Autodiscriminates All Standard 1D Symbologies

System Interface: IS4823 and IS4825

USB, TTL RS232

Print Contrast: 35% Minimum Reflectance Difference

IS4813 and IS4815

Decode Dependent

Number of Characters

Read: IS4823 and IS4825

Up to 80 data characters (Maximum)

Roll, Pitch, Yaw 42°, 68°, 52°

Mechanical

Dimensions: See pages 6 – 8 for detailed specifications.

IS4813 / IS4815 Non-Decode Engine

8 g (0.282 oz)

IS4823 / IS4825 Bracketed (-1) Assembly

15 g (0.529 oz)

Weight (Maximum):

IS4823 / IS4825 Non-Bracketed (-1) Assembly

10 g (0.353 oz)

IS4813 / IS4815 Non-Decode Engine

10-PIN ZIF Connector

Termination:

IS4823 / IS4825 Decode PCB

12-PIN ZIF Connector

Enclosure and

Mounting:

See pages 6 – 13 for detailed specifications on enclosure and
mounting guidelines.