Ttl, rs232, 3.3v / 5v (77-77142), Ttl, rs232 3.3v / 5v – Metrologic Instruments IS4823 User Manual

Page 32

Advertising
background image

28

TTL, RS232, 3.3V / 5V

12-Pin ZIF Connector

Pin

Signal Name

Function

1

TTLINV

Input: TTL RS232 Polarity Control with 33.2k ohm Pull-Up

2

+3.3V or 5.0V Power: Supply Voltage Input, +3.3V ± 0.3V or +5.0V ± 5%

3

GND

Ground: Power and Signal Ground

4

RxD

Input: TTL Level RS232 Receive Data

5

TxD

Output: TTL Level RS232 Transmit Data

6

CTS

Input: TTL Level Clear to Send

7

RTS

Output: TTL Level RS232 Request to Send

8

PWRDWN

Output: Active High = IS4823 is in Power Down Mode

9 nBEEPER

Output: Active Low, Signal Capable of Sinking Current
See Detailed Electrical Specifications starting on page 23.

10 nGood

Scan

Output: Active Low, Signal for Sinking Current (Good Scan)
See Detailed Electrical Specifications starting on page 23.

11 nEXT

WAKE

Input: Active Low, Signal Used to Bring Engine Out of
Power Down

12 EXT

Trig

Input: Active Low, Signal Used as Trigger Input to Activate
the Engine

10-Pin ZIF Connector

Pin

Signal Name

Function

1 SDA

I

2

C Data (Bi-Directional) – Devices Function as Auxiliary

Devices

2

GND

Ground: Power and Signal Ground

3

GND

Ground: Power and Signal Ground

4 Scan

Sense

Level changes from High to low or low to high when the
laser changes direction at the start of the scan line

High = Bar

5 Data

Low = Space
High = Engine OFF

6 Scan

Enable

Low = Engine ON
High = Laser OFF

7 Laser

Enable

Low = Laser ON

8 NC

No

Connection

9

+3.3V or 5.0V Power: Supply Voltage Input, +3.3V ± 0.3V or +5.0V ± 5%

Figure 20.

10 SCL

I

2

C Data (Bi-Directional) – Devices Function as Auxiliary

Devices

Advertising
This manual is related to the following products: