Operation, Installation, Cable specifications – Milan Technology CCSF30XX-100 User Manual

Page 4: Snmp, Continued power the media converter, Coax cable, Fiber cable

Advertising
background image

CCSCF30xx-11x

6

Operation

After installation, the media converter should function without
operator intervention. Use the status LEDs to monitor the media
converter operation in the network.

SDC

Green on

The coax link is up.

Green flashing

The coax link is in loop-back mode.

Yellow on

AIS (Alarm Indication Signal) on the

coax link.

SDF

Green on

The fiber link is up.

Green flashing

The fiber link is in loop-back mode.

Yellow on

AIS (Alarm Indication Signal) on the

fiber link.

PWR Green on

The media converter is connected to

external power.

SNMP

See the on-line documentation that comes with Transition Networks
FocalPoint™ software for applicable commands and usage.

Use SNMP at an attached terminal or at a remote location to monitor the
media converter by monitoring:

Media converter power

Line build-out

DS3 / T3 / E3 mode

Coax link and fiber link status (local and/or remote)

Coax loop-back and fiber loop-back status (local only)

AIS detected on coax link and fiber link (local and/or remote)

Hardware/software mode

Also, use SNMP to enter network commands that:

Enable/disable loop-back on the copper link (local only)

Enable/disable loop-back on the fiber link (local only)

Installation

-- Continued

Power the Media Converter

The media converter is powered through the Transition
Network’s PointSystem™ chassis.

CCSCF

FL

CL

SDC

PWR

SDF

RX

TX

Fiber

RX

TX

Coax

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

[email protected] -- Click the “Transition Now” link for a live Web chat.

7

Cable Specifications

Coax Cable

DS3 / E3: 75 ohm coax cable with BNC connectors

Fiber Cable

Single mode fiber (recommended):

9 µm

Multimode fiber (recommended):

62.5/125 µm

Multimode fiber (optional):

100/140, 85/140, 50/125 µm

CCSCF3011-100

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

CCSCF3013-100

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

CCSCF3014-100

1310 nm single mode

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -31.0 dBm

max: -8.0 dBm

Link Budget:

16.0 dB

CCSCF3015-100

1310 nm single mode

Fiber Optic Transmitter Power:

min: -8.0 dBm

max: -2.0 dBm

Fiber Optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Link Budget:

26.0 dB

CCSCF3016-100

1310 nm single mode

Fiber-optic Transmitter Power:

min: -5.0 dBm

max: 0.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Link Budget:

29.0 dB

CCSCF3017-100

1550 nm single mode

Fiber-optic Transmitter Power:

min: -5.0 dBm

max: 0.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Link Budget:

29.0 dB

CCSCF3018-100

1300 nm multimode

Fiber-optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -33.5 dBm

max: -14.0 dBm

Link Budget:

14.5 dB

CCSCF3019-100

1310 nm single mode

Fiber-optic Transmitter Power:

min: -15.2 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.5 dBm

max: -3.0 dBm

Link Budget:

17.3 dB

CCSCF3029-100

1310 nm (TX) / 1550 nm (RX) simplex

CCSCF3029-101

1550 nm (TX) / 1310 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -13.0 dBm

max: -6.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.0 dBm

max: -3.0 dBm

Link Budget:

19.0 dB

CCSCF3029-102

1310 nm (TX) / 1550 nm (RX) simplex

CCSCF3029-103

1550 nm (TX) / 1310 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -8.0 dBm

max: -3.0 dBm

Fiber-optic Receiver Sensitivity:

min: -33.0 dBm

max: -3.0 dBm

Link Budget:

25.0 dB

Advertising