CCSCF30xx-10x

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

Cable Specifications -- Continued

CCSCF3039-100

1300 nm multimode

Fiber-optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

The fiber optic transmitters on this device meet Class I Laser safety requirements
per IEC-825/CDRH standards and comply with 21 CFR1040.10 and
21CFR1040.11.

Technical Specifications

For use with Transition Networks Model CCSCF30xx-10x or equivalent

Standards

FCC Class A; EN 55022 Class A; EN 55024; ANSI
T1.102-1993; ETSI TBR-24; ITU-T G.703 G.823 for
jitter tolerance; G.775 for loss of signal; Telecordia
GR-499CORE & GR-253-CORE

Data Rate

DS3 / T3 = 44.7 Mb/s
E3 = 34.4 Mb/s

Dimensions

3.4" x 5" x 0.87" (86 mm x 182 mm x 22 mm)

Weight

3 oz. (91 g) (approximately)

Power Consumption

6.0 Watts

MTBF

478,000 (MIL217F2 V5.0) (MIL-HDBD-217F)
1,333,000 (Bellcore7 V5.0)

Environment

Tmra*:

0 to 60°C (32° to 140°F )

Storage Temp:

-20° to 85°C (-4° to 185°F)

Humidity:

5 to 95%, non condensing

Altitude:

0 to 10,000 feet

Warranty

Lifetime

*Manufacturer’s rated ambient temperature: Tmra range for this slide-in-module
depends on the physical characteristics and the installation configuration of the
Transition Networks PointSystem™ chassis in which this slide-in-module will be
installed.

The information in this user’s guide is subject to change. For the most up-to-date
information on the CCSCF30xx-10x media converter, view the user’s guide on-
line at: www.transition.com.

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.

CAUTION: Visible and invisible laser radiation when open. Do not stare into
the beam or view directly with optical instruments.

CAUTION: Use of controls, adjustments or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.

[email protected] -- Click the “Transition Now” link for a live Web chat.

9

Troubleshooting

If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:

1.

Is the PWR (Power) LED illuminated?
NO

•

Ensure the media converter slide-in-module is installed properly in
the chassis.

•

Ensure the power cord is properly installed in the chassis and at the
external power source.

•

Ensure the external power source provides power.

•

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

•

Proceed to step 2.

2.

Is the SDC (Signal Detect / Coax) LED illuminated green?
NO

•

Check the coax cables for the proper connection.

•

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

•

Proceed to step 3.

3.

Is the SDF (Signal Detect / Fiber) LED illuminated green?
NO

•

Check the fiber cables for proper connection.

•

Verify that the TX and RX cables on the local media converter are
connected to the RX and TX ports, respectively, on the remote media
converter.

•

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

•

Proceed to step 4.

4.

Is the SDC (Signal Detect / Coax) LED flashing green?
YES

•

The coax link is in loop-back mode. For normal operation, set the
loop-back switch to the center (normal) position.

•

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

NO

•

Proceed to step 5.

5.

Is the SDF (Signal Detect / Fiber) LED flashing green?
YES

•

The fiber link is in loop-back mode. For normal operation, set the
loop-back switch to the center (normal) position.

•

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

NO

•

Proceed to step 6.