2. controls for ce models – Miller Electric SuitCase 8VS User Manual

Page 20

Advertising
background image

OM-1599 Page 16

5-2. Controls For CE Models

Ref. 803 626-A / Ref. 802 706-A / Ref. 203 745 / Ref. 203 749

1

Power Control Switch

2

Trigger Hold Switch

Depress the upper part of the

switch (turns trigger hold On) to

weld without holding gun trigger

throughout the weld cycle.
To start weld, press and release

gun trigger. To end weld, press and

release gun trigger.
Depress the lower part of the trigger

hold switch to turn trigger hold Off.
3

Purge Switch

Press switch to momentarily ener-

gize gas solenoid and purge air

from gun, and to adjust shielding

gas regulator.
4

Wire Speed Control

Use control to adjust wire speed

within range selected by switch.
5

Jog Switch

Use Jog position to momentarily

feed welding wire at speed set on

Wire Speed control without ener-

gizing welding circuit or shielding

gas valve.
6

HI/LO Range Switch

Use switch to select high or low wire

speed range. High range is 100 to

700 ipm. Low range is 50 to 350

ipm.
7

CC/CV Switch

Use switch to match wire feeder

with welding power source output.
Close and latch door.

1

Front Panel

Internal Control Panel

3

4

5

Internal Side View

6

7

2

HI

CV

CC

LO

Advertising