1. controls, Power – Miller Electric OM-225A User Manual

Page 16

Advertising
background image

OM-225 Page 14

SECTION 3 – OPERATION

3-1.

Controls

ST-801 394

1

2

3

5

1

Power Switch

2

Power Light

Power light comes On when Power switch is
placed in On position.

When unit is turned On, the power light blinks
for a short time (3 seconds for 230 VAC, 1 se-
cond for 460 VAC) to indicate a delay during
which the circuits are being initialized.

If the voltage selector switch (see Section
2-7) is set for 230 VAC and 460 VAC is ap-
plied to the unit, the power light continues to
blink and the unit is not operational.

The power light also blinks to indicate the
need for a manual power reset. This occurs

whenever the torch parts are disassembled
while the unit is turned On.

3

Ready Light

Use light to tell if unit is ready for operation.

Ready light comes on when Power switch is
placed in On position, indicating that all safe-
ty shutdown systems are okay.

If Ready light does not come on, check
Trouble Lights.

4

Trouble Lights (See Section 4-2)

5

Output Control

Use control to set cutting output.

Gas/air automatically flows at the set
pressure.

Setting Gas/Air Pressure

Place controls in positions shown. Only gas/
air circuit is activated when Power switch is
turned On with Output Control in Gas/Air Set
Position.

6

Pressure Gauge

7

Pressure Adjustment Knob

Lift knob and turn to adjust pressure. Push
knob down to lock in setting.

Place output control in desired cutting
output.

Setting Gas/Air Pressure

7

I

O

POWER

30

40

50

6

30

50

40

1

5

4

Set Controls

Turn On Gas/Air Supply

Adjust Pressure

Select Desired

Amperage To Be-

gin Cutting

Set To

70 PSI (482 kPa)

Requires 70–150 PSI

(482–1034 kPa) Supply

Advertising