Fireplace specifications, Gas vent rule – Maxon Telecom MPB3328CNE User Manual

Page 5

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

5

F

E

B

D

C

G

Top View

FRAMING
SPACERS

(Top and Sides

and Rear)

Front View

3 (76)

A

J

H

Flue Outlet For B-Vent Connection

OPTIONAL ELECTRICAL

INLET KNOCKOUT

REQUIRING A FIELD

PROVIDED JUNCTION

BOX (Either Side)

GAS INLET
(Either Side
and bottom)

NOTE - Hood shown

as positioned

in louvered

front model.

ELECTRICAL INLET

2-3/4 x 2 (70 x 51) COVER
PLATE with KNOCKOUT)

K

1/2 (13)

3 (76)

1

³⁄₈

(35)

(140)

5-1/2

9-3/8

(238)

2

(53)

Right Side View

(140)

5-1/2

9-3/8

(238)

1-3/8

(35)

Left Side View

GAS INLET

(See Also

Right Side View)

ELECTRICAL INLET

(See Also

Right Side View)

3

(76)

OUTSIDE AIR

SHUTTER

8-15/16

(227)

7-3/8
(187)

ELECTRICAL

INLET

(Optional)

.

o

N

l

e

d

o

M

A

B

C

D

E

F

G

.

n

i

5

3

8

/

1

-

8

/

1

-

2

3

9

1

2

/

1

-

9

2

5

3

8

/

1

-

8

/

-

6

1

/

7

-

2

5

8-3/4

13

330

406

16

406

16

406

16

m

m

2

9

8

6

1

8

3

8

4

9

4

7

2

9

8

2

3

6

6

1

3

7

2

1

222

.

n

i

8

/

1

-

0

4

8

/

1

-

7

3

4

2

2

/

1

-

4

3

8

/

1

-

0

4

8

/

7

-

9

2

1

6

1

/

5

1

-

4

5

8-3/4

m

m

9

1

0

1

3

4

9

0

1

6

6

7

8

9

1

0

1

9

5

7

9

7

3

7

2

1

22

2

.

n

i

8

/

1

-

0

4

8

/

1

-

7

3

4

2

2

/

1

-

9

3

8

/

1

-

5

4

8

/

7

-

4

3

6

1

/

7

-

7

1

6

8-3/4

m

m

6

4

1

1

3

4

9

0

1

6

3

0

0

1

6

4

1

1

6

8

8

3

4

4

2

5

1

222

MPB3328

MPB3530

MPB4035

MPB4540

in.

mm

33-1/8

841

432

765

841

699

21-1/2

33-1/8

4

546

102

273

27-1/2

17

30-1/8

24-7/8

621

12-7/16

10-3/4

J

K

H

6-1/2

165

FIREPLACE SPECIFICATIONS

Figure 4

Venting

GAS VENT RULE

Gas vent caps are not permitted within 8 feet
(2.4 mm) of a vertical wall or similar obstruc-
tion. Gas vent caps that are located 8' or more
from a portion of a building which extends at
an angle greater than 45° upward from the
horizontal may terminate in accordance with
Table 4 and Figure 5, provided that in no case
shall any discharge opening on the cap be less
than 2' (610 mm) horizontally from the roof
surface (National Fuel Gas Code ANSI Z223.1
(NFPA 54) 7.6.2) (CAN/CGA B149).

Figure 5

Termination Heights For Vents

Above Flat Or Sloped Roofs

Ref. NFPA 54 / ANSI Z223.1, 7.6

Roof Pitch

Feet

Meters

Flat to 6/12

1' 0"

0.3

Over 7/12 to 9/12

2' 0"

0.6

Over 10/12 to 12/12

4' 0"

1.2

Over 13/12 to 16/12

6' 0"

1.8

Over 17/12 to 21/12

8' 0"

2.4

Table 4

Roof Pitch is X/12

Minimum Height from Roof to
Lowest Discharge Opening

X

12

1" (25 mm)
Minimum

Gas Vent Rule

Note: Venting terminals shall not be recessed
into a wall or siding.

Advertising