OM-216 655 Page 7

SECTION 3 − INSTALLATION

3-1.

Gun Recommendation Table

Process

Gun

GMAW − Hard or Corded Wires

M25 Or M40

FCAW − Self-Shielding Wires

GA-40GL

1

CV Welding Power Source with
14 pin Amphenol Receptacle

2

Interconnecting Control Cord
(Required)

3

Weld Cable (Required)

4

Work

3-2.

Equipment Connection Diagrams

4

3

2

1

3-3.

14-Pin Plug Information

Pin*

Pin Information

A

24 volts ac with respect to pin G.

A

J

K

I

B

Contact closure to A completes 24 volts ac contactor control circuit.

A

J

B

K

I

C

L

N

H

G

Circuit common for 24 volts AC circuit.

C

L

N

H

D

M

G

C

+10 volts dc output to remote control with respect to pin D.

D

M

G

E

F

D

Remote control circuit common.

E

0 to +10 volts dc input command signal from remote control with respect to pin D.

H

Voltage feedback; 0 to 10 volts dc, 1 V/10 arc volts

*The remaining pins are not used.

Ref. S-0004-A

3-4.

Specifications

Type of Input

Power

Welding Power

Source Type

Wire Feed

Speed Range

Wire

Diameter

Range

Welding

Circuit Rating

Overall

Dimensions

Weight

24 Volts AC Single

Phase

5 Amperes 50/60

Hz

Constant Voltage

(CV) DC with 14

pin and Contactor

Control

0 to 20 mpm

(0 to 788 ipm)

0.6 to 2.0 mm

(0.23 to 5/64 in)

Max Spool Weight:

15 kg (33.0 lb.)

100 Volts,

500 Amperes,

100%

Duty Cycle

Length: 650 mm

(25.5 in)

Width: 220 mm

(8.65 in)

Height: 420 mm

(16.5 in)

ST 44 Series &

ST Blu Fab

(22.0 kg (48 lbs)

ST 44 Ultra-Lite

15.0 kg (33 lbs)