NPort 5110 Series User’s Manual

Web Console Configuration

5-9

Port alias

Setting

Factory Default

Necessity

1 to 15 characters
(E.g., PLC-No.1)

None Optional

“Port alias” is included to allow easy identification of the serial devices that are connected to
NPort 5110’s serial port.

Serial Parameters

ATTENTION

Check the serial communication parameters in your Serial Device’s user’s manual. You should
set up NPort 5110’s serial parameters with the same communication parameters used by your
serial devices.

Baud rate

Setting

Factory Default

Necessity

110 bps to 230.4 Kbps

115.2 Kbps

Required

Data bits

Setting

Factory Default

Necessity

5, 6, 7, 8

8

Required

When the user sets Data bits to 5 bits, the Stop bits setting will automatically change to 1.5 bits.

Stop bits

Setting

Factory Default

Necessity

1, 1.5, 2

1

Required

Stop bits will be set to 1.5 when Data bits is set to 5 bits.

Parity

Setting

Factory Default

Necessity

None, Even, Odd, Space, Mark

None

Required

Flow control

Setting

Factory Default

Necessity

None, RTS/CTS, DTR/DSR, Xon/Xoff

RTS/CTS

Required

FIFO

Setting

Factory Default

Necessity

Enable, Disable

Enable

Required

NPort 5110’s serial ports provide a 16-byte FIFO both in the Tx and Rx directions. To prevent
data loss during communication, disable the FIFO setting when your serial device does not have a
FIFO.

Interface

Model

Port

Settings

Factory Default

Necessity

NPort 5110

1

RS-232

RS-232

Required