OM-203 034 Page 28

6-4. Voltmeter/Ammeter Help Displays

.

All directions are in reference to
the front of the unit. All circuitry

referred to is located inside the

unit.

1

Help 0 Display

Indicates a shorted thermistor RT2

on the left side of the unit. If this dis-

play is shown, contact a Factory

Authorized Service Agent.
2

Help 1 Display

Indicates a malfunction in the pri-

mary power circuit. If this display is

shown, contact a Factory Autho-

rized Service Agent.
3

Help 2 Display

Indicates a malfunction in the ther-

mal protection circuitry located on

the left side of the unit. If this display

is shown, contact a Factory Autho-

rized Service Agent.
4

Help 3 Display

Indicates the left side of the unit has

overheated. The unit has shut down

to allow the fan to cool it (see Sec-

tion 4-2). Operation will continue

when the unit has cooled.
5

Help 4 Display

Indicates a malfunction in the ther-

mal protection circuitry located on

the right side of the unit. If this dis-

play is shown, contact a Factory

Authorized Service Agent.
6

Help 5 Display

Indicates the right side of the unit

has overheated. The unit has shut

down to allow the fan to cool it (see

Section 4-2). Operation will contin-

ue when the unit has cooled.
7

Help 6 Display

Indicates that the input voltage is

too low and the unit has automati-

cally shut down. Operation will con-

tinue when the voltage is within

±

15% of the operating range. If this

display is shown, have an electri-

cian check the input voltage.
8

Help 7 Display

Indicates that the input voltage is

too high and the unit has automati-

cally shut down. Operation will con-

tinue when the voltage is within

±

15% of the operating range. If this

display is shown, have an electri-

cian check the input voltage.
9

Help 8 Display

Indicates a malfunction in the sec-

ondary power circuit of the unit. If

this display is shown, contact a

Factory Authorized Service Agent.
10 Help 9 Display
Indicates a shorted thermistor RT1

on the right side of the unit. If this

display is shown, contact a Factory

Authorized Service Agent.

2

A

V

3

A

V

4

A

V

HE.L P−1

HE.L P−2

HE.L P−3

5

A

V

HE.L P−4

6

A

V

HE.L P−5

7

A

V

HE.L P−6

8

A

V

HE.L P−7

9

A

V

HE.L P−8

A

V

HE.L P−0

A

V

HE.L P−9

10

1

Advertising
This manual is related to the following products: