Moxa Technologies IA5150 User Manual

Page 53

Advertising
background image

NPort IA5150/5250 Series User’s Manual

Web Console Configuration

5-28

Ethernet Modem

Setting

Value

Notes

Necessity

TCP port

valid port No.

The TCP port that other devices must use to

contact this device. To avoid conflicts with

standard TCP ports, the default is set to 4001.

Required

0

TCP connection is not closed due to an idle serial

line.

TCP alive
check time

1 to 99 min.

TCP connection is automatically closed by this

device if there is no TCP activity for the given

time.

Optional


AT Commands

NPort IA5150/5250 supports the following common AT commands used with a typical modem:

No. AT command

Description

Remarks

1 ATA

Answer

manually

2

ATD <IP>:<Port>

Dial up the IP address : Port No.

3 ATE

ATE0=Echo

OFF

ATE1=Echo ON (default)

4 ATH

ATH0=On-hook

(default)

ATH1=Off-hook

5

ATI, ATI0, ATI1, ATI2 Modem version

reply “OK” only

6

ATL

Speaker volume option

reply “OK” only

7

ATM

Speaker control option

reply “OK” only

8

ATO

On line command

9

ATP, ATT

Set Pulse/Tone Dialing mode

reply “OK” only

10 ATQ0,

ATQ1

Quiet

command

(default=ATQ0)

11 ATSr=n

Change the contents of S register

See “S registers”

12 ATSr?

Read the contents of S register

See “S registers”

13 ATV

Result code type
ATV0 for digit code,
ATV1 for text code

0=OK
1=connect (default)
2=ring
3=No carrier
4=error

14 ATZ

Reset (disconnect, enter command
mode and restore the flash settings)

15 AT&C

Serial port DCD control

AT&C0=DCD always on
AT&C1=DTE detects connection by
DCD on/off (default)

Advertising