16 AT&D

Serial port DTR control
AT&D0=recognize DTE always
ready
AT&D1, AT&D2=reply DTE when
DTR On (default)

17 AT&F

Restore

manufacturer’s

settings

18 AT&G

Select guard time

reply “OK” only

19 AT&R

Serial port RTS option command

reply “OK” only

20 AT&S

Serial port DSR control

reply “OK” only

21 AT&V

View

settings

22 AT&W

Write current settings to flash for
next boot up


S Registers

No. S Register

Description & default value

Remarks

1 S0

Ring to auto-answer (default=0)

2 S1

Ring counter (always=0)

no action applied

3 S2

Escape code character (default=43

ASCII “+”)

4

S3

Return character (default=13 ASCII)

5 S4

Line feed character (default=10

ASCII)

6 S5

Backspace character (default= 8

ASCII)

7 S6

Wait time for dial tone (always=2,

unit=sec)

no action applied

8 S7

Wait time for carrier (default=3,

unit=sec)

9 S8

Pause time for dial delay (always=2,

unit=sec)

no action applied

10 S9

Carrier detect response time

(always=6, unit 1/10 sec)

no action applied

11 S10

Delay for hang up after carrier

(always=14, unit 1/10 sec)

no action applied

12 S11

DTMF duration and spacing
(always=100 ms)

no action applied

13 S12

Escape code guard time
(default=50, unit 1/50 sec)

to control the idle time for “+++”


TCP alive check time

Setting

Factory Default

Necessity

0 to 99 min

7 min

Optional

0 min: TCP connection is not closed due to an idle TCP connection.

1 to 99 min: NPort IA5150/5250 automatically closes the TCP connection if there is no TCP
activity for the given time.