NPort IA5150/5250 Series User’s Manual

Web Console Configuration

5-30

Local TCP port

Setting

Factory Default

Necessity

1 to 65535

4001

Required

The TCP port that other devices must use to contact this device. To avoid conflicts with standard
TCP ports, the default is set to 4001.

Reverse Telnet Mode

TCP alive check time

Setting

Factory Default

Necessity

0 to 99 min

0

Optional

Specifies the time slice for checking if the TCP connection is alive. If no response, NPort IA will
disconnect the original connection.

Inactivity time

Setting

Factory Default

Necessity

0 to 65535 ms

0

Optional

Idle time setting for auto-disconnection. 0 min. means it will never disconnect.

Local TCP port

Setting

Factory Default

Necessity

1 to 65535

4001

Optional

Each of NPort IA’s serial ports is mapped to a TCP port. To avoid conflicts with TCP ports, set port
numbers to 4001 for port1, 4002 for port 2, etc. (like the default values).

Map <CR-LF>

Setting

Factory Default

Necessity

CR, LF, or CR-LF

CR-LF

Optional

If data received through NPort IA’s Ethernet port is sent using the “enter” command, the data will be
transmitted out the serial port with an added
(1) “carriage return + line feed” if you select the <CR-LF> option

(i.e., the cursor will jump to the next line, and return to the first character of the line)

(2) “carriage return” if you select the <CR> option

(i.e., the cursor will return to the first character of the line)

(3) “line feed” if you select the <LF> option.

(i.e., the cursor will jump to the next line, but not move horizontally)