4. rear panel connections, 5. 14-pin plug information – Miller Electric D-64 User Manual

Page 17

Advertising
background image

OM-1582 Page 13

Ref. 800 353-B

Tools Needed:

4-4.

Rear Panel Connections

1

”Y” Adapter Gas Hose
(Supplied)

2

Shielding Gas Valve Fitting

Requires fitting with 5/8-18 right-
hand threads.

3

Weld Cable Terminal

4

Jumper Weld Cable

5

Weld Cable

6

Optional Current Sensor
Connections

7

14-Pin Cord

8

Power Switch

9

Rating Label Location

9/16, 5/8 in

3/16 in

1

2

3

4

5

4

5

6

7

8

9

6

4-5.

14-Pin Plug Information

Pin*

Pin Information

A

24 volts ac with respect to socket G.

B

Contact closure to A completes 24 volts ac contactor control circuit.

A

J

G

Circuit common for 24 volts AC circuit.

A

J

B

K

I

C

+10 volts dc output to remote control with respect to socket D.

C

L

N

H

D

M

G

D

Remote control circuit common.

D

M

G

E

F

E

0 to +10 volts dc input command signal from remote control with respect to socket D.

H

Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.

F

Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.

*The remaining pins are not used.