9

Audible Indicators

When the MS7100 scanner is in operation, it provides audible feedback.
These sounds indicate the status of the scanner. Eight settings are available for
the tone of the beep (normal, 6 alternate tones and no tone). To change the
tone, refer to the MetroSelect Programming Guide MLPN 2407.

One Beep

*

When the scanner first receives power, the red LED will turn
on, then the green LED will flash and the scanner will beep once.
(The green LED will remain on for the duration of the beep.) The
scanner performs this startup sequence, the scanner is ready to
scan.

When the scanner successfully reads a bar code, the green LED
will flash and the scanner beeps once (if programmed to do so).
If the scanner does not beep once and the green light does not
flash, then the bar code has not been successfully read.

Razzberry Tone

This is a failure indicator. Refer to failure modes page 10.

Three Beeps - during operation

***

During operation of the scanner, the green LED will flash
while the scanner simultaneously beeps three times (while going
into programming mode).

The green LED will continue to flash until the unit exits program
mode. Upon exiting program mode, the scanner will beep three
times and the green LED will stop flashing. When configured, 3
beeps can also indicate a communications timeout during normal
scanning mode.

When using one-code-programming, the scanner will beep
three times (the current selected tone), followed by a short
pause then by a high tone and a low tone. This tells the user
that the single configuration bar code has successfully con-
figured the scanner.

Three Beeps - on power up

This is a failure indicator. Refer to failure modes page 10.