RS-232 only

SYMPTOM

Power-up OK and scans OK but does not communicate properly to the host

POSSIBLE CAUSE(S)

SOLUTION

Com port at the host is not working or

Check to make sure that the baud rate and

configured properly

parity of the scanner and the communica-tion
port match and the program is looking for
“RS-232" data

Cable not connected to the proper com

Check to make sure that the baud rate and

port

parity of the scanner and the communica-tion
port match and the program is looking for
“RS-232" data

Com port not operating properly

Check to make sure that the baud rate and
parity of the scanner and the communica-tion
port match and the program is looking for
“RS-232" data

SYMPTOM

The host is receiving data but the data does not look correct

POSSIBLE CAUSE(S)

SOLUTION

The scanner and host may not be

Check that the scanner and the host are

configured for the same interface font

configured for the same interface font

SYMPTOM

Characters are being dropped

POSSIBLE CAUSE(S)

SOLUTION

Intercharacter delay needs to be added

Add some intercharacter delay to the

to the transmitted output

transmitted output by using the MetroSelect
Programming Guide MLPN 2407