SYMPTOM

The unit powers up properly, lasers come on, but the unit does not scan and does not
beep when a bar code is presented

POSSIBLE CAUSE(S)

SOLUTION

Beeper disabled. No tone selected

Enable beeper. Select tone

Scanning a particular symbology that is

UPC/EAN, Code 39, interleaved 2 of 5,

not enabled

Code 93, Code 128 and Codabar are enabled
by default. Verify that the type of bar code
being read has been selected

The scanner has been programmed for a

Verify that the bar code that is being scanned

character length lock, or a minimum

falls into the criteria. (Typical of Non-

length and bar code being scanned does
not satisfy the programmed criteria

UPC/EAN codes.) (The scanner defaults to
a minimum of 4 character bar code
)

SYMPTOM

The scanner scans a bar code but the scanner locks up (green LED comes on and stays
on) after the first scan

POSSIBLE CAUSE(S)

SOLUTION

The scanner is configured to support

If the scanner is setup to support ACK/NAK,

some form of host handshaking but is

RTS/CTS, XON/XOFF or D/E, verify that

not receiving the signal

the host cable and host are supporting the
handshaking properly

SYMPTOM

The scanner scans and transmit but the data is not correct at the host

POSSIBLE CAUSE(S)

SOLUTION

The scanner’s data format does not

Verify that the scanner’s data format

match the host system requirements

matches that required by the host. Make sure
that the scanner is connected to the proper
host port