Caution – Milwaukee LSM40MP-2 User Manual

Page 21

Advertising
background image

21

Step 4. FIELD WIRING

CAUTION

Ground supply lead must be con-

nected to the wire attached to the

green ground screw located on

the outlet box. See

Figures 35 and

36

. Failure to do so will result in a

potential safety hazard. The appli-

ance must be electrically grounded

in accordance with local codes or,

in the absence of local codes, the

National Electrical Code, ANSI/

NFPA 70-latest edition. (In Canada,

the current CSA C22-1 Canadian

Electrical Code).

CAUTION: Label all wires prior to disconnec-

tion when servicing controls. Wiring errors can

cause improper and dangerous operation.

ATTENTION: Au moment de l'entretien des

commandes, étiquetez tous les fils avant de

les débrancher. Des erreurs de cáblage peu-

vent entraîner un fonctionnement inadéquat

et dangereux.

Verify proper operation after servicing.

S'assurer que l'appareil fonctionne adé-

quatement une fois l'entretien terminé.

Figure 34

Figure 35

Thermopile

TH

TP

TH

TP

Millivolt Wiring Diagram

If any of the original wire as supplied must be replaced,

it must be replaced with

Type AWM 105° C – 18 GA. wire

*OR OPTIONAL WALL-MOUNTED ON/OFF SWITCH OR

OPTIONAL REMOTE CONTROL RECEIVER

*Turn the appliance-mounted ON/OFF burner control switch

to the OFF position if an optional

control switch is installed.

Factory Wired

Field Wired

Schematic Representation Only

APPLIANCE-MOUNTED ON/OFF SWITCH

ELECTRONIC

WIRING DIAGRAM

BLK

W

120 V.

24 V.

TRANSF

ELECTRONIC IGNITION

CONTROL BOARD

*WALL MOUNTED ON/OFF SWITCH (OPTIONAL)

OR REMOTE CONTROL RECEIVER

APPLIANCE MOUNTED

ON/OFF SWITCH

PILOT BURNER

IGNITER-SENSOR

ASSEMBLY

GAS VALVE

EV2

EV1

GROUND

CONNECTOR

GREEN LED

WHITE (6)

WH

ITE

(2

0)

OR

AN

GE

(2

0)

BLACK (20)

PU

RP

LE

(9

)

GR

EE

N (

12

)

BLUE (20)

BLACK (16)

WHITE

FIELD WIRED

FACTORY WIRED

*Turn The Appliance-Mounted ON/OFF Burner Control Switch

To The OFF Position If An Optional Control Switch Is Installed

Black

White

Ground

Junction Box

120 VAC

3..Remove.the..cover.plate's.knockout.and.then.

feed.the.power.supply.wire.through.the.knock-

out.opening.and.into.the.unit.junction.box.

4..Connect.the.black.power.supply.wire.to.the.

power outlet's.red.pigtail.lead.and.the.white.

power.supply.wire.to.the.

common terminal.of.

the.outlet.as.shown.in.

Figures 35 and 36..

5.. Connect the ground supply wire to the

pigtail lead attached to outlet's green

ground screw.

6...Appliance-mounted.ON/OFF.burner.control.

switch.(rocker.switch).is.factory.installed..

Optional.wall-mounted..switch,.or.one.of.

the.optional.remote.control.kits.may.also.

be.used..

7...If. wall-mounted. ON/OFF. control. is. to. be.

used,.mount.it.in.a.convenient.location.on.

a.wall.near.the.fireplace.

8..If.an.optional.control.is.to.be.used,.wire.it.in.

the.low.voltage.circuit.(see.

Figure 35).

Note: The supplied 15 feet of 2 conductor wire

has one end of each conductor connected in

parallel with the appliance mounted ON/OFF

burner control switch and the other end of each

conductor placed on top of the unit.

CAUTION: Do Not connect the optional wall

switch to a 120V power supply.

9..If. an. optional. control. switch. is. installed,.

turn.the.appliance-mounted.ON/OFF.burner.

control.switch.to.the.OFF.position.

10.After. the. wiring. is. complete,. replace. the.

cover.plate.

See Figure 36 for detailed

drawing of junction box /

receptacle wiring

Refer.to.Section.A.for.millivolt.appliances.and.

Section. B. for. electronic. appliances.. The. gas.

valve.is.set.in.place.and.pre-wired.at.the.factory.

on.both.models.

A. Millivolt Wiring (See Figure 34)..

1...Appliance-mounted.ON/OFF.burner.control.

switch.(rocker.switch).is.factory.installed..

Optional. wall-mounted. . switch,. or. one. of.

the.optional.remote.control.kits.may.also.

be.used..

2..If.wall-mounted.ON/OFF.control.is.selected.

mount.it.in.a.convenient.location.on.a.wall.

near.the.fireplace.

3..Wire.the.control.switch.within.the.millivolt.

control.circuit..using.the.15.feet.of.2.conduc-

tor.wire.supplied.with.the.unit.

Note: The supplied 15 feet of 2 conductor wire

has one end of each conductor connected

to the gas valve circuit and the other end of

each conductor placed on top of the unit.

CAUTION: Do Not connect the optional wall

switch to a 120V power supply.

4. If. an. optional. control. switch. is. installed,.

turn.the.appliance-mounted.ON/OFF.burner.

control.switch.to.the.OFF.position.

B. Electronic Wiring

(See Figures 35 and 36)

Note: The electronic appliance must be con-

nected to the main power supply.

1..Route. a. 3-wire. 120Vac. 60Hz. 1ph. power.

supply.to.the.appliance.junction.box.

2..Remove.the.electrical.inlet.cover.plate.from.

the.side.of.the.unit.by.removing.the.plate's.

securing. screws. (see Figure 12 on Page

10).