Milwaukee LSM40MP-2 User Manual

Page 28

Advertising
background image

28

Glass Door

Assembly

Fireplace

Finish Combustible

Or Non-Combustible

Material

Bottom Of

Fireplace

1/8 Inch

Minimum

Door Track

Finish Combustible

Or Non-Combustible

Material

Front Face

Of Fireplace

Floor Panel

Figure 55

Figure 54

Non-combustible.materials,.such.as.surrounds.and.other.appliance.trim,.

may.be.installed.on.the.appliance.front.face.with.the.exceptions..

Vertical.installation.clearances.to.combustible.mantels.vary.according.

to.the.depth.of.the.mantel...See.Figure 9...Mantels.constructed.of.non-

combustible.materials.may.be.installed.at.any.height.above.the.appliance.

opening.

Combustible.materials.may.project.beyond.the.side.of.the.fireplace.opening.

as.long.as.it.is.kept.within.the.shaded.area.illustrated.in.Figure 10.

* Insulation is NOT ALLOWED in the clearance zones around vent

components. Keep this area free from combustible materials.

2 Foot Vertical

Vent & 90° Elbow

3" Min.

(76 mm)*

Top of

Appliance

8-3/8" Min.

(213 mm)

Combustible

materials are

allowed above

this point on

the face of the

appliance.

The gray shaded

area must be

non-combustible

or Dura Rock

Header

(2x4’s)

Spacers

Top of Door Frame

Fireplace (right side)

Combustible

Finished Wall

Materials

1

*

Installations with horizontal terminations which have minimum

vertical vent height only will require 4”(102mm) minimum

side clearance as shown in shaded zone above. All other

installations require 1" (25mm) minimum side clearance as

specified in Table 4 on Page 5.

1

Figure 53

FINISHING REQUIREMENTS

Wall Details

Complete.finished.interior.wall..To.install.the.appliance.facing.flush.with.

the.finished.wall,.position.framework.to.accommodate.the.thickness.of.

the.finished.wall.(Figure 53).

A.hearth.extension.is.not.required.with.this.appliance..If.a.hearth.extension.

is.used,.there.are.two.methods.of.installation...One,.the.finish.combustible.

or.non-combustible.material.could.be.ended.by.butting.up.against.the.

front.face.of.the.fireplace.and.the.floor.panel.(refer to Figure 54).

Two,.the.finish.combustible.or.non-combustible.material.could.be.ended.

below.the.fireplace (refer to Figure 55)...Remove.the.floor.panel.as.shown.

in.Figure 54.by.removing.the.screws.on.the.right.side.of.the.panel.and.

sliding.the.left.side.away.from.the.tab...Discard.the.screws.and.floor.panel...

It is critical that there is at least a 1/8" gap between the bottom of the

door track and the surface of the finish material.