Warning and Safety
instructions

,

These warning and safety

instructions are in addition to those
given at the beginning of this
booklet.

~

H

2

O

2

solution must only be used in

the special containers and adapters
provided by the Ecolab and Dr. Weigert
companies.

~

Important: observe the

manufacturer's safety instructions as
given on their safety data sheet.

~

Be especially careful when handling

H

2

O

2

solution. It is an irritant chemical.

Observe all current safety instructions
pertaining to its use.
Wear protective gloves and goggles.

~

Empty containers must be disposed

of in accordance with the
manufacturer's instructions.

~

H

2

O

2

solution must not be mixed

with other chemicals. This could cause
a serious chemical reaction, e. g. the
release of harmful vapours or gases.

~

Only use tenside cleaning agents

supplied by Ecolab or Dr. Weigert.

Connecting the H

2

O

2

solution

container

The connection hose for the H

2

O

2

solution container is identified by a
black label. The connection hose is
supplied without a safety cap as the
container for hydrogen peroxide will
vary depending on supplier.

^ Connect the supplier's safety cap to

the connection hose (black).

^ Then connect this to the H

2

O

2

solution container.

^ Then start the

DOS2-FILL

programme.

Unlike with other chemical agents the
H

2

O

2

solution container must be fully

emptied before it is exchanged for a
new one.

Do not replace the H

2

O

2

solution

container with a new one until the

FILL

DOS 2 CONTAINER

message is

displayed. After connecting the new
container you must run the

DOS2-FILL

programme.

If the

CHECK DISPENSING SYSTEM 2

message appears you should check
the container as well as the dispensing
system. The programme will stop
automatically.

Special processes - OXIVARIO and ORTHOVARIO