All electrical work must be carried
out by a suitably qualified and
competent person in accordance
with local and national safety
regulations (BS 7671 in the UK).

– Connection should be made via a

suitable isolator with an on-off switch
which is easily accessible for
servicing after the machine has been
installed.

– An electrical safety test must be

carried out after installation and after
any servicing work. It is therefore
essential that the on-off switch is
easily accessible.

– When switched off there must be an

all-pole contact gap of at least 3 mm
in the isolator switch.

– For extra safety it is advisable to

protect the machine with a suitable
residual current device (RCD).

– Check that the phase rotation is

correct when connecting the
machine. Failure to do so could have
an adverse effect on the circulation
pump and impair the wash quality.

– Equipotential bonding should be

carried out.

– For technical data see data plate or

wiring diagram supplied.

The machine must only be operated
with the voltage, frequency and fusing
shown on the data plate.

Further notes on electrical
connection are given on the
Installation diagram supplied with
the machine.

The data plate showing relevant test
marks (VDE, DVGW etc.) is located on
the cover located behind the service
panel on the unclean side of the
machine.

The wiring diagram is supplied with
the machine.

WARNING

THIS APPLIANCE MUST BE

EARTHED

Electrical connection

59