Water service/drains, Water inlet lines, Drain connections – Manitowoc Ice Q 800 User Manual

Page 10: Water supply and drain line sizing/connections

Advertising
background image

Installation Instructions Section 2

2-4

Water Service/Drains

Water Inlet Lines
Follow these guidelines to install water inlet lines:

• Do not connect the ice machine to a hot water

supply. Be sure all hot water restrictors installed
for other equipment are working. (Check valves
on sink faucets, dishwashers, etc.)

• If water pressure exceeds the maximum

recommended pressure, obtain a water pressure
regulator from your Manitowoc distributor.

• Install a water shut-off valve for both the ice

making and condenser water lines.

• Insulate water inlet lines to prevent condensation.

• Use teflon tape to seal threaded fittings.

Important

Install sump trough drain plug before starting the
ice machine.

Drain Connections

Follow these guidelines when installing drain lines to
prevent drain water from flowing back into the ice
machine and storage bin:

• Drain lines must have a 1.5 inch drop per 5 feet

of run (2.5 cm per meter), and must not create
traps.

• The floor drain must be large enough to

accommodate drainage from all drains.

• Run separate bin and ice machine drain lines.

Insulate them to prevent condensation.

• Vent the bin and ice machine drain to the

atmosphere. Do not vent the condenser drain on
water-cooled models.

CAUTION

Plumbing must conform to applicable
codes.


WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS

Location

Water

Temperature

Water

Pressure

Ice Machine

Fitting

Tubing Size Up to Ice

Machine Fitting

Ice Making

Water Inlet

33°F (0.6°C) Min.

90°F (32.2°C)

Max.

20 psi (137.9 kPA) Min.

80 psi (551.5 kPA) Max.

3/8” Female

Pipe Thread

3/8” (9.5 mm)

minimum inside

diameter

Ice Making

Water Drain

--- ---

1/2” Female

Pipe Thread

1/2” (12.7 mm)

minimum inside

diameter

Condenser

Water Inlet

33°F (0.6°C) Min.

90°F (32.2°C)

Max.

20 psi (137.9 kPA) Min.

150 psi (1034.2 kPA)

Max.

3/8” Female Pipe Thread

Condenser

Water Drain

--- ---

1/2” Female

Pipe Thread

1/2” (12.7 mm)

minimum inside

diameter

Bin Drain

--- ---

3/4” Female

Pipe Thread

3/4” (19.1 mm)

minimum inside

diameter

Advertising