Harvest sequence water purge – Manitowoc Ice Q 800 User Manual

Page 16

Advertising
background image

Ice Machine Operation Section 3

3-4

HARVEST SEQUENCE WATER PURGE

15

30

45

The harvest sequence water purge adjustment may be
used when the ice machine is hooked up to special
water systems, such as a de-ionized water treatment
system.

Important

The harvest sequence water purge is factory-set at
45 seconds. A shorter purge setting is not
recommended. This can increase water system
cleaning and sanitizing requirements.

• The harvest sequence water purge may be set to

15, 30, or 45 seconds.

• During the harvest sequence water purge, the

water fill valve energizes and de-energizes by
time. The water purge must be at the factory
setting of 45 seconds for the water fill valve to
energize during the last 15 seconds of the water
purge. If it is set to less than 45 seconds, the
water fill valve will not energize during the water
purge.

WARNING

Disconnect the electrical power to the ice machine
at the electrical disconnect before proceeding.

For your safety, and to eliminate errors, we
recommend that a qualified service technician make
the harvest water purge adjustment.

CONTROL

BOARD

WATER PURGE

ADJUSTMENT

SV1617

Water Purge Adjustment

Advertising