OM-1500-4 Page 14

3-7.

Setting Internal DIP Switches

Position Settings And Results For DIP Switch S1

On = Current detect over-
ride. For welding power
sources that don’t provide
current feedback through
the 14-pin receptacle. Fac-
tory set automatic run-in is
inactive.

Off = Current must be detected
from power sources that provide
current feedback through the
14-pin receptacle to go from auto-
matic run-in to welding condition.
Factory-set automatic run-in wire
speed is active.

Remove wrapper.

1

DIP Switch S1 On Motor
Board PC1

w

Setting Current Detect
Override (S1-1)

Current detect override is used to
disable automatic run-in when a
welding power source is used that
doesn’t provide current feedback
through the 14-pin receptacle.

Install wrapper when finished.

1

Ref. 802 946 / Ref. 802 944

.

In the DIP switch S1 illustrations,
the elevated slider on each switch
is show in white. For example, the
switches above are all in the Off
position.

.

When DIP switch positions are changed, the unit must be
turned Off and then On again in order for the new settings
to be active. DIP switches are only read on power up.

Tools Needed:

1/4 in

This illustration shows

the factory setting of S1.

S1-1 And S1-2

S1-1 And S1-2

Current Detect Override

Factory Default