Ls600 pump — inspection – Multiquip Mayco Concrete Pump LS600 User Manual

Page 25

Advertising
background image

MAYCO LS600 PUMP — OPERATION AND PARTS MANUAL — REV. #4 (9/15/11) — PAGE 25

LS600 PUMP — INSPECTION

2. If the hydraulic oil level is low, remove the cap just

above the oil level sight glass (Figure 13) and add the
correct amount of hydraulic oil to bring the hydraulic
oil level to a normal safe operating level. (Use Shell oil
Tellus 68 or Mobil oil DFE26).

Figure 13. Hydraulic Oil Filler Hole

3. Check the oil level in the

lubrication box. If low, fill

with up to 3 gallons of SAE #30 motor oil (Figure 14).
The oil level must be checked daily. The lubrication
box should be serviced as described in the maintenance
section.

Figure 14. Filling the Lubrication Box

Advertising