DCA-15SPXU4— OPERATION MANUAL — REV. #0 (03/31/11) — PAGE 23

1

120 VAC GFCI Receptacle

This120 VAC, 20 amp GFCI (Duplex Nema 5-20R) receptacle
can be used anytime the generator is in operation. Remember
the load output (current) of the GFCI receptacle is dependent
on the load requirements of the U, N, and V output terminal
lugs.

Pressing the

reset button resets the GFCI receptacle after

being tripped. Pressing the

Test Button (See Figure 6) in

the center of the receptacle will check the GFCI function.
Both receptacles should be tested at least once a month.

Figure 6. G.F.C.I. Receptacle

Turn the

voltage regulator control knob (Figure 10) on the

control panel to obtain the desired voltage. Turning the knob
clockwise will

increase the voltage, turning the knob counter-

clockwise will

decrease the voltage.

Figure 7. 120/240V CS6369 Twist-Lock

Auxiliary Receptacle

DCA-15SPXU4 — OUTPUT TERMINAL PANEL FAMILIARIZATION

Twist Lock Dual Voltage 120/240 VAC Receptacle (Option)

There is one CS-6369 120/240V, 50 amp auxilliary twist-lock
receptacle (Figure 7) provided on the output terminal panel.
This receptacle is protected by a 50 amp circuit breaker.

Figure 10. Voltage Regulator Control Knob

L5-30R Twist Lock 120 VAC Receptacle

There is one L5-30R, 120 VAC 30 amp auxilliary twist-lock
receptacle (Figure 8) provided on the output terminal panel.

L6-30R Twist Lock 240 VAC Receptacle (Option)

There is one L6-30R, 240 VAC 30 amp auxilliary twist-lock
receptacle (Figure 9) provided on the output terminal panel.

Figure 8. 120 VAC L5-30R Twist-Lock

Auxiliary Receptacle

Figure 9. 240 VAC L6-30R Twist-Lock

Auxiliary Receptacle

CS-6369

TWIST-LOCK

RECEPTACLE

SINGLE-PHASE

120/240 VAC

50 AMP OUTPUT