Dca-15spxu4 — generator start-up procedure – Multiquip Whisperwatt 60 Hz Generator DCA-15SPXU4 User Manual

Page 32

Advertising
background image

PAGE 32 — DCA-15SPXU4— OPERATION MANUAL — REV. #0 (03/31/11)

DCA-15SPXU4 — GENERATOR START-UP PROCEDURE

Figure 33. Voltage Adjust Control Knob

7. The generator's AC-voltmeter (Figure 32) will display the

generator’s output in VOLTS. If the voltage is not within
the specified tolerance, use the voltage adjustment
control knob (Figure 33) to increase or decrease the
desired voltage.

Figure 32. Voltmeter

8. Place the

main, GFCI, and aux. circuit breakers in the

ON position (Figure 34).

9. Observe the generator's ammeter (Figure 35) and verify

it reads the anticipated amount of current with respect
to the load. The ammeter will only display a current
reading if a load is in use.

Figure 35. Ammeter (Load)

10. The generator will run until manually stopped or an

abnormal condition occurs.

Figure 31. Ammeter (No Load)

6. The ammeter (Figure 31) will indicate

zero amps with

no load applied. When a load is applied, the ammeter
will indicate the amount of current that the load is
drawing from the generator.

5. Set the Speed Control Switch to the RUN position

(Figure 30).

Figure 30. Speed Control Switch (RUN)

Figure 34. Main, GFCI, and Aux.

Circuit Breakers (ON)

Advertising
This manual is related to the following products: