5-4.

Circuit Breakers CB1 And CB2

Ref. ST-801 245-A / Ref. 183 308

1

Circuit Breaker CB1

2

Circuit Breaker CB2

CB1 protects 110 volt ac portion of
Remote 14 receptacle (see Section
3-6) from overload.

CB2 protects 24 volt ac portion of
Remote 14 receptacle from
overload.

Press button to reset breaker.

1

2

CB1

CB2

5-5.

Troubleshooting

Trouble

Remedy

No weld output; unit completely inop-

Place line disconnect switch in On position (see Section 3-8).

erative.

Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 3-8).

Check for proper input power connections (see Section 3-8).

No weld output; meter display On.

If using remote control, be sure Mode Selector switch is in a position that provides output control at
Remote 14 receptacle.

Check, repair, or replace remote control.

Unit overheated. Allow unit to cool with fan On (see Section 3-2).

Erratic or improper weld output.

Use proper size and type of weld cable (see Section 3-5).

Clean and tighten all weld connections.

No 110 volts ac output at duplex recep-
tacle, Remote 14 receptacle.

Reset circuit breaker CB1 (see Section 5-4).

No 24 volts ac output at Remote 14 re-
ceptacle.

Reset circuit breaker CB2 (see Section 5-4).