Section 5 − operation, 1. controls with meters – Miller Electric 12VS User Manual

Page 25

Advertising
background image

OM-1500-19 Page 21

SECTION 5 − OPERATION

5-1. Controls With Meters

Ref. 804 006-B

1

Power Control Switch

2

Trigger Hold Switch

Trigger hold allows operator to weld without

holding gun trigger.
To use trigger hold function, place trigger

hold switch in the ON position.
The operator must hold the trigger for a mini-

mum of 2 seconds, but no longer than 6 sec-

onds before releasing it. Welding will contin-

ue when trigger is released.
To stop welding, press and release the trig-

ger.
3

Jog/Purge Switch

Pressing the Jog switch allows the operator

to jog wire without energizing the contactor

or gas valve.
Pressing the Purge switch allows the opera-

tor to purge gas lines before welding and to

preset gas flow rate at the flowmeter.
4

Voltmeter

Displays actual arc voltage or open circuit

voltage at the feeder.
5

Wire Speed / Amperage Meter

Displays wire speed in Inches per Minute. To

display wire speed in Meters per Minute, see

Section 4-10.
Amperage displayed at the feeder is approxi-

mate. Refer to power source for actual am-

perage. To display Amperage, see Section

4-10.
6

Wire Speed Control

Use control to adjust wire speed within the

speed range selected by the wire speed

range switch, located on the inner control

panel.
7

HI/LO Speed Range Switch

Use switch to select speed range. High

range is 50 to 780 Inches per minute. Low

range is approximately half of high range.
8

CC/CV Switch

Use switch to match feeder with the output of

the power source.
9

Soft Start Switch

The Soft Start feature provides a smooth

start during most weld conditions. When the

trigger is pulled, the wire speed is approxi-

mately 25% of the weld wire speed, as set by

the wire speed control knob. After an arc is

established, the wire speed increases to the

weld wire speed.
When using small diameters wire, or with in-

verter power sources, it may be necessary to

turn switch off to obtain smooth starts.
After adjusting the switches, close and latch

the door before welding.

Front Panel

Internal Control Panel

Internal Side View

7

1

2

OFF

3

9

8

4

5

6