OM-223 605 Page 21

6-3. Voltage Control And Digital Meters (For Models With Meters Only)

3

804 182-A

1

2

1

Voltmeter

The voltmeter displays actual or

preset voltage from the welding

power source through the 14−pin

control cable.
2

Wire Speed Meter

The wire speed meter is factory set

to display inches per minute. If dis-

play of meters per minute is de-

sired, see Section 5-12.
3

Voltage Control

Use control to adjust voltage output

of welding power source.

.

You can adjust the preset volt-
age display on the wire feeder

to match your power source’s

display by adjusting P2 on mo-

tor control board PC1. See

Section 7-2 for location of P2.

SECTION 7 − MAINTENANCE

7-1. Routine Maintenance

Y Disconnect power before maintaining.

3 Months

Replace

unreadable

labels.

Clean and

tighten

weld

terminals.

Repair or

replace

cracked

weld

cable.

Check

14-pin cord.

Check gas

hose and

fittings.

Check gun

cable.

Replace

cracked

parts.

6 Months

Blow out or vacuum

inside. During heavy

service, clean

monthly.

Or

Clean

drive rolls.

Advertising