DS1215 TIME REGISTERS DESCRIPTION Figure 17–4

OSC

7

6

5

4

3

2

1

0

0.1 SEC

0

0

HR

0

12/24

0

0

0

0

0

0

0

0

0

10 YEAR

RANGE (BCD)

00–99

00–59

00–59

01–12

01–07

01–31

01–12

00–99

CLOCK

0

1

2

3

4

5

6

7

REGISTER #

0.01 SEC

10’s OF SECONDS

SECONDS

10’s OF MINUTES

MINUTES

10

A/P

HOUR

DAY

10 DATE

DATE

10

MON

MONTH

YEAR

00–23

REGISTERS

The time information is contained in eight registers that
are each 8 bits long. After the 64–bit recognition pattern
has been received, data in these registers is accessed
one bit at a time which is shown conceptually in
Figure 17–4. It is recommended that data written to the
RTC be handled in groups of 8 bits corresponding to the
register bytes in order to prevent erroneous results.

Register data is always in BCD format except for the
hours register (register 3), whose format changes de-
pending upon the state of bit 7. If bit 7 is high, the
12–hour mode is selected and bit 5 of the hours register
becomes an AM/PM indicator; if bit 7 is low, the 24–hour
mode is selected and bit 5 becomes the second
10–hour bit (20–23 hours). Figure 17–5 contains exam-

ples that illustrate the content of these registers for dif-
ferent modes and times.

SPECIAL BITS

Bit 5 of the days register (register 4) is the control bit for
the clock micropower oscillator. Clearing bit 5 to a logic
0 enables the oscillator for normal operation; setting bit
5 to a logic 1 disables the oscillator and halts the time-
keeping. It is recommended that bit 5 always be cleared
to 0.

Register locations shown as logic 0’s in Figure 17–4 will
always return a 0 when being read. Write operations to
these bit locations are ignored by the clock and have no
effect on its operation.